PRATT & LAMBERT -- FIRE RETARDANT WHITE -- 8010-00N050659
=====================  Product Identification  =====================

Product ID:FIRE RETARDANT WHITE
MSDS Date:09/09/1992
FSC:8010
NIIN:00N050659
=== Responsible Party ===
Company Name:PRATT & LAMBERT
Box:22
City:BUFFALO
State:NY
ZIP:14240
Country:US
Info Phone Num:718-873-6000
Emergency Phone Num:718-873-6000;800-255-3924
CAGE:77359
=== Contractor Identification ===
Company Name:PRATT & LAMBERT
Box:City:BUFFALO
State:NY
ZIP:14240
Country:US
Phone:716-873-6000
CAGE:77359

=============  Composition/Information on Ingredients  =============

Ingred Name:TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: 5%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:MELAMINE; (MELAMINE RESIN)
CAS:108-78-1
RTECS #:OS0700000
Fraction by Wt: 5%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:PARAFFIN WAXES AND HYDROCARBON WAXES, CHLORINATED;
    (CHLORINATED PARAFFIN)
CAS:63449-39-8
RTECS #:RV0450000
Fraction by Wt: 5%
OSHA PEL:COMPLETE
ACGIH TLV:N/K 

Ingred Name:ACETIC ACID, VINYL ESTER; (VINYL ACETATE)  (SARA III). LEL:
    3%. UEL: 13%.
CAS:108-05-4
RTECS #:AK0875000
Fraction by Wt: < 5%
OSHA PEL:10 PPM;15 STEL
ACGIH TLV:10 PPM;5,A3 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:INGEST: MAY CAUSE GASTROINTESTINAL
    IRRITATION. INHAL: MAY CAUSE RESPIRATORY IRRITATION. EYE: MAY CAUSE
    EYE IRRITATION. SKIN: MAY CAUSE TRANSIENT SKIN IRRITATION.
Explanation of Carcinogenicity:CHLORINATED PARAFFIN WAX: IARC
    MONOGRAPHS ON THE EVAL OF CARCIN RISK OF CHEMS TO MAN, VOL 48, PG
    55, 1990: (SUPP DATA)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL POIS CTRL CTR, HOSPITAL EMER ROOM/MD IMMED.
    INHAL: REMOVE TO FRESH AIR. EYE: FLUSH W/LARGE AMOUNTS OF WATER FOR
    AT LEAST 15 MIN, LIFTING UPPER AND LOWER LIDS OCCASIONALLY. GET MED
    ATTN. SK IN: REMOVE CONTAMINATED CLTHG. WASH AFFECTED AREA W/SOAP
    AND WATER. NOTE TO MD: ANY TREATMENT THAT MIGHT BE REQUIRED FOR
    OVEREXP SHOULD BE DIRECTED AT THE CONTROL OF SYMPS & THE CLINICAL
    CNDTNS.

=====================  Fire Fighting Measures  =====================

Lower Limits:ING 4
Upper Limits:ING 4
Extinguishing Media:WILL NOT BURN. EXTINGUISHING MEDIA SUITABLE FOR
    SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.

==================  Accidental Release Measures  ==================

Spill Release Procedures:CONFINE IN SMALL AREA; USE ABSORBENT TO CLEAN
    UP. PLACE IN CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:PROTECT FROM FREEZING.
Other Precautions:DO NOT TAKE INTERNALLY. CLOSE CONTAINER AFTER EACH
    USE. KEEP AWAY FROM CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF APPLIED BY SPRAYING, USE AN APPROPRIATE,
    PROPERLY FITTED NIOSH/MSHA APPROVED RESPIRATOR TO REMOVE THE SPRAY
    MIST. REFER TO OSHA 29 CFR 1910.134 "RESPIRATORY PROTECTION".
Ventilation:NATURAL VENTILATION SHOULD BE ADEQUATE UNDER NORMAL
    CONDITIONS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPVD SFTY SPECS W/SIDESHLD(SUPDAT)
Other Protective Equipment:NOT LIKELY TO BE NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN: GROUP B. NTP 6TH ANNUAL REPORT ON CARCINOGENS, 1991:
    ANTICIPATED TO BE CARCINOGEN. EYE PROT: . FACESHIELD AS NECESSARY.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>162F,>72C
Vapor Pres:HVR/AIR
Spec Gravity:1.3
Evaporation Rate & Reference:SLOWER THAN DIETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:50

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
    WELDING OR CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE & CARBON
    DIOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE AND
    LOCAL LAWS. AS PRODUCED THIS PROD IS NOT A WASTE. IF DISCARDED AS
    IS, IT IS NOT CLASSIFIED AS A HAZ WASTE UNDER RCRA.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.